8x8 DVIDual Link MatrixGEF-DVI-848DL-PBUser Manualwww.gefenpro.com
6PANEL LAYOUTBack Panel37861452
7PANEL DESCRIPTIONSBack Panel1 110 / 220 V AC (50/60 Hz) Power ReceptacleConnect the included AC power cord from this receptacle to an availableelect
8CONNECTING THE 8X8 DVI DUAL LINK MATRIXHow to Connect the 8x8 DVI Dual Link Matrix1.Connect up to 8 DVI Dual Link source devices to the inputs on the
9FRONT PANEL DISPLAYMain DisplayThe Main Display of the GefenPRO 8x8 DVI Dual Link Matrix is a 16 character 2 line display. This display will show the
10FRONT PANEL DISPLAYDisplaying the Routing StatusFrom the main screen, press the Select button. When the arrow cursor is next to OUTPUT, pressing th
11IR REMOTE CONTROL UNITLayout and Description (RMT-848IR)1 LED Button Press IndicatorThis LED will be activated momentarily each time a button is pre
12Installing the Battery1.Remove the battery cover on the back of the IR Remote Control unit.2. Insert the included battery into the open battery slot
13IR REMOTE CONTROL UNITSetting the IR ChannelIn the event that IR commands from other remote controls interfere with the supplied IR Remote Control u
14IR REMOTE CONTROL UNITIR Remote Control Key MappingEach input and output on the 8x8 DVI Dual Link Matrix is represented by a button on the IR Remote
15EDID MANAGEMENTEDID. What is it and what is it used for?Under normal circumstances, a source device (digital and analog) will requireinformation abo
16IP CONFIGURATIONConfi guring the IP AddressThe8x8 DVI DL Matrix supports IP-based control using Telnet or the built-in xWeb-based GUI. To set up IP
17RS-232 SERIAL CONTROLRS232 SettingsBits per second ...
18TELNET / RS-232 COMMANDSEDID ManagementCommandDescription#dynamic_edidEnables / disables dynamic EDID#edidbatoloRead downstream EDID and stores in a
19TELNET / RS-232 COMMANDS#edidbatolo CommandThe #edidbatolo command reads the downstream EDID and stores it to any local input. Up to eight inputs c
20TELNET / RS-232 COMMANDS#ediddetolo FunctionThe #ediddetolo function stores the Default EDID (640x480) in the specifi edLocal EDID inputs. Up to eig
21TELNET / RS-232 COMMANDS#ediddstoba FunctionThe #ediddstoba function reads the downstream EDID and stores it to a specifi edEDID bank.Syntaxy:#edidds
22TELNET / RS-232 COMMANDS#ediddstolo FunctionThe #ediddstolofunction reads the downstream EDID and stores it to a Local EDID input.Syntaxy:#ediddstol
23TELNET / RS-232 COMMANDS#lock_edid FunctionThe #lock_edid function secures the Local EDID and disables the automaticloading of the downstream EDID a
24TELNET / RS-232 COMMANDS#prbaedid FunctionThe #prbaedid function reads the EDID fi le from the specifi ed bank and sends to serial port.Syntaxy:#prbae
25TELNET / RS-232 COMMANDS#prdsedid FunctionThe #prdsedid function reads the downstream EDID and sends it to the serial port.Syntaxy:#prdsedid param1P
ASKING FOR ASSISTANCERev A9Technical Support:Telephone (818) 772-9100 (800) 545-6900Fax (818) 772-9120Technical Support Hours:8:00 AM - 5:00 PM
26TELNET / RS-232 COMMANDS#predidst FunctionThe #predidst function reads the downstream EDID. This function displays atable containing details relati
27TELNET / RS-232 COMMANDS#prloedid FunctionThe #prloedid function reads the local EDID of a specifi ed input and spools it to the serial port.Syntaxy:
28TELNET / RS-232 COMMANDSIP / Telnet Confi gurationCommandDescription#display_telnet_welcomeSet Telnet welcome message on login#ipconfi g Displays all
29TELNET / RS-232 COMMANDS#ipconfi g CommandThe #ipconfi g command displays the current TCP/IP settings for the matrix.Syntaxy:#ipconfi gParameters:NoneE
30TELNET / RS-232 COMMANDS#resetip CommandThe #resetip command resets all TCP/IP settings to factory defaults.Syntaxy:#resetipParameters:None Notes:T
31TELNET / RS-232 COMMANDS#set_telnet_pass CommandThe #set_telnet_pass command sets the Telnet password. The maximum lengthof the password is 20 char
32TELNET / RS-232 COMMANDS#set_telnet_username CommandThe #set_telnet_username command sets the Telnet user name. The maximum length of the user name
33TELNET / RS-232 COMMANDS#show_telnet_pass CommandThe #show_telnet_pass command shows the Telnet password for login(if required).Syntaxy:#show_telnet
34TELNET / RS-232 COMMANDS#show_ver_data CommandThe #show_ver_data command displays the hardware and fi rmware version of the matrix.Syntaxy:#show_ver_
35TELNET / RS-232 COMMANDS#snetmask CommandThe #snetmask command sets the IP network mask. Dot-decimal notation must be used when specifying the IP n
CONTENTS1 Introduction2 Operation Notes3 Features4 Panel Layout - Front5 Panel Descriptions6 Panel Layout - Back7 Panel Descriptions8 Connecting A
36TELNET / RS-232 COMMANDSRoutingCommandDescription#callpresetRecalls a routing / mask preset#prpresetPrints the routing preset table#savepresetSaves
37TELNET / RS-232 COMMANDS#prpreset CommandThe #prpreset command displays the routing preset table.Syntaxy:#prpresetParameters:NoneExamplep:#prpresetP
38TELNET / RS-232 COMMANDS#savepreset CommandThe #savepreset command saves the current routing state to the specifi edpreset. Any masked outputs will
39TELNET / RS-232 COMMANDSr CommandThe r command routes the specifi ed input to the specifi ed outputs. Syntaxy:r param1 param2 [param3...param9]Paramet
40TELNET / RS-232 COMMANDSs CommandThe s command routes the specifi ed input to all outputs.Syntaxy:s param1Parameters:param1 Input [1 - 8]Example
41TELNET / RS-232 COMMANDSMaskingCommandDescription#maskoutMasks the selected (video) output(s)#unmaskoutUnmasks the selected output(s)#maskout Comman
42TELNET / RS-232 COMMANDS#unmaskout CommandThe #unmaskout command unmasks the specifi ed outputs. If param1 = 0, then all outputs will be unmasked.Sy
43TELNET / RS-232 COMMANDSMiscellaneousCommandDescription#activeboloActivates the boot loader#fadefaultResets the matrix to factory default routing#he
44TELNET / RS-232 COMMANDS#fadefault CommandThe #fadefault command disables the EDID lock state, sets the default routingstate (1-1, 2-2, 3-3, etc.) a
45TELNET / RS-232 COMMANDS#help CommandThe #help command displays help on the specifi ed command. If param1 is notspecifi ed, then the full list of com
1INTRODUCTIONCongratulations on your purchase of the GefenPRO 8x8 DVI Dual Link Matrix.Your complete satisfaction is very important to us.GefenPROIn t
46TELNET / RS-232 COMMANDS#set_input_name CommandThe #set_input_name command provides a name to the selected input.For example, “Input 1” could be ren
47TELNET / RS-232 COMMANDS#set_output_name CommandThe #set_output_name command provides a name to the selected output. For example, “Output 1” could
48TELNET / RS-232 COMMANDS#show_voltageThe #show_voltage command provides voltage information for the matrix.Syntaxy:#show_voltageParameters:NoneExamp
49TELNET / RS-232 COMMANDSf CommandEnables / disables 5V on pin 14 of the specifi ed DVI input. This command isused when connecting the Receiver modul
50TELNET / RS-232 COMMANDSl CommandThe l (lower-case “L”) command displays the link status of each input. If the input is receiving a dual-link signa
51TELNET / RS-232 COMMANDSm CommandThe m command displays the current matrix status and routing information.Syntaxy:mParameters:NoneExamplep:m Output
52WEB INTERFACEView Matrix StatusMatrix StatusDisplays the current routing status of each input and output on the matrix.RefreshClick to refresh the M
53WEB INTERFACESwitch OutputsUsed to route the specifi ed input to the selected output(s). To route a source,place a check mark next to each Output.
54WEB INTERFACEPresetthe down-arrow on theown list to select the preseton (1-16). Click the Save et button to save the preset.Recall PresetClick the
55WEB INTERFACESave Output NameSelect the DVI output to rename from the pull-down list. Type the name of the output in the Output Name fi eld. Click
OPERATION NOTES2READ THESE NOTES BEFORE INSTALLING OROPERATING THE GEFENPRO 8X8 DVI DUAL LINK MATRIX• The 8x8 DVI Dual Link Matrix does not support HD
56WEB INTERFACEManage EDIDSet Input to Default EDIDEDID StatusDisplays the current EDID status for each input on the matrix andindicates the current L
57WEB INTERFACESet Default EDIDPlace a check mark next to the input(s) that should be set to the default EDID.Click the Set Default EDID button to app
58WEB INTERFACEUpload EDIDLoad EDID fi lePlace a check mark next to the input(s) that will receive the EDID data from thefi le. The EDID fi le must be i
59WEB INTERFACEDownload EDIDDownload EDID File to PCSelect the radio button next to the output, containing the EDID to be downloaded. Click the Downl
60WEB INTERFACECopy EDIDSelect Source to Copy from / Select Input(s) to Copy toClick the radio button next to the input or output containing the EDID
61WEB INTERFACEEDID Lock StateUpdate EDID Lock StateSecures the Local EDID and disables the automatic loadingof the downstream EDID after the Matrix i
62WEB INTERFACEMaskingMatrix Mask Status / ChangeDisplays the current masking status for each output.MaskClick the Mask button to mask the selected ou
63WEB INTERFACEIP Confi gurationIP SettingsAssigns IP address, subnet, gateway, HTTP listening port, and Telnet port.Note that the MAC address can not
64WEB INTERFACEBackup / RestoreThe Backup / Restore feature for the 8x8 DVI Dual Link Matrix is not currently implemented and will be available in a f
65WEB INTERFACEPower ManagementPower StatusEnabling this feature will store the +5V status for that input prior to shutting downthe matrix. This pres
3FEATURESFeatures• Increases productivity•Supports resolutions up to 1920x1200 (Single Link) and 3840x2400 (Dual Link)• Front panel control buttons f
66WEB INTERFACEPower Lock StateIn the case of an accidental power loss to the matrix, the +5V state for eachinput can be preserved.Set the specifi ed P
67NETWORK CABLE WIRING DIAGRAMGefen recommends the TIA/EIA-568-B wiring option. Please adhere to the table below when fi eld-terminating the cable for
68FIRMWARE UPDATEFirmware Update ProcedureThe following items are required to update fi rmware:•RS-232 Terminal (e.g. Windows-based PC running HyperTer
69FIRMWARE UPDATE8. A message will appear in the terminal program:Waiting for the fi le to be sent ... (press ‘a’ to abort)9. In Hyperterminal, click T
70RACK MOUNT SAFETY INFORMATIONa.Maximum recommended ambient temperature: 45 ˚C (104 ˚F).b.Increase the air fl ow as needed to maintain the recommended
71SPECIFICATIONSVideo Amplifi er Bandwidth ...2 x 165 MHzDVI Connector ...
72WARRANTYGefen warrants the equipment it manufactures to be free from defects in material and workmanship.If equipment fails because of such defects
73LICENSINGlwIP is licenced under the BSD licence:Copyright (c) 2001-2004 Swedish Institute of Computer Science.All rights reserved.Redistribution and
Rev A920600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefenpro.com [email protected]
4PANEL LAYOUTFront Panel234516
5PANEL DESCRIPTIONSFront Panel1 Control ButtonsThese buttons are used to navigate the LCD menu system. See pages 9 and 10 for more information.◄ -
Kommentare zu diesen Handbüchern