Seite 1 - GEF-3GSDI-16416-PB

Audio Embedder 3GSDI 16 16xSOURCESDISPLAYS3G-SDI Matrixw/ Push Button ControlsRelease A2User ManualGEF-3GSDI-16416-PB

Seite 3 - Warranty Information

16 16xSOURCESDISPLAYS3G-SDI Matrixw/ Push Button Controls 01 Getting StartedPanel Layout ...

Seite 4

page | 2Front ID Name Description1 On/Off Used to power-ON or power-OFF the matrix. 2 Mode buttons Used to control various features on the

Seite 5 - Operating Notes

Back ID Name Description1 Ref Loop Connect a BNC cable from the Ref Loop connector to a signal analyzer, in order to view the signal on the R

Seite 6 - Features and Packing List

page | 4Getting StartedFrontID Name Description1 Activity indicator This LED glows bright orange when a key is pressed on the remote. 2 Buttons (1 - 1

Seite 7

page | 5IR Remote Control UnitGetting StartedBack(shown with cover removed)ID Name Description1 DIP switch bank Use these DIP switches to set the IR c

Seite 8 - Table of Contents

page | 6Getting StartedInstalling the BatteryThe IR remote control unit ships with two batteries. Only one battery is required for operation. The se

Seite 9

Connecting the 16x16 3G-SDI Matrix1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear panel of the 16x16 3GSDI Push Button Mat

Seite 11 - 01 Getting Started

16 16xSOURCESDISPLAYS3G-SDI Matrixw/ Push Button Controls 02 Operating the 16x16 3G-SDI MatrixFront Panel Controls ...

Seite 12 - Panel Layout

16x16 3G-SDI Matrix w/ Push Button ControlsImportant Safety InstructionsiiGENERAL SAFETY INFORMATION 1. Read these instructions.2. Keep these instru

Seite 13

page | 10Operating the 16x16 3G-SDI Matrix w/ Push Button ControlsFront Panel ButtonsThere are a total of 38 buttons on the front panel of the matrix.

Seite 14 - IR Remote Control Unit

page | 11Front Panel LCD ScreenThe front-panel of the 16x16 3G-SDI Matrix w/ Push Button Controls contains a 16-character 2-line LCD display which is

Seite 15 - Getting Started

page | 12Operating the 16x16 3G-SDI Matrix w/ Push Button ControlsRouting Inputs to OutputsThe following example illustrates the routing process. An

Seite 16 - Setting the IR Channel

page | 13Routing BasicsOperating the 16x16 3G-SDI Matrix w/ Push Button Controls 5. Press the Set button on the front panel, once again. Press

Seite 17 - Installation

page | 14Getting the Current Routing StatusTo display the current routing status of the Matrix, press any one of the Input or Output buttons on the fr

Seite 18

page | 15Inputs to Outputs 1. Press the A6 button on the bottom row of buttons. By querying an input, all Outputs that are connected (routed) to the

Seite 19 - 16x16 3G-SDI Matrix

page | 16Saving the Current Routing StateThe 16x16 3G-SDI Matrix w/ Push Button Controls allows routing (and masking) states to be saved to internal n

Seite 20 - Front Panel Controls

page | 174. Select a preset location by pressing any of the rst eight input buttons (A1 - A8). The matrix supports up to eight preset locations. Fo

Seite 21 - Front Panel LCD Screen

page | 18Recalling a Saved Routing StateThe 16x16 3G-SDI Matrix w/ Push Button Controls allows saved routing (and masking) states to be recalled from

Seite 22 - ROUTING MODE

page | 19Masking Outputs“Masking” prevents the output device (display, etc) from receiving an output signal. Instead of powering-down or disconnecting

Seite 23 - 3GSDI 16x16

16x16 3G-SDI Matrix w/ Push Button ControlsWarranty InformationGefen warrants the equipment it manufactures to be free from defects in material and wo

Seite 24

page | 204. Once the Set button is pressed, the LCD display will indicate that the masking process was successful: 5. After a few moments, the

Seite 25

page | 21GEFEN 3GSDI 16x16Getting the Current Masking StatusIf the masking state is unknown, it can be queried using the Mask button. Alternatively,

Seite 26 - SAVE CURRENT SET

page | 22MaskingOperating the 16x16 3G-SDI Matrix w/ Push Button ControlsUnmasking OutputsOnce an output (or multiple outputs) has been masked, it can

Seite 27

page | 234. Once the Set button is pressed, the LCD display will indicate that the unmasking process was successful: 5. After a few moments, t

Seite 28 - RECALL SAVED SET

page | 24Locking the matrix will prevent any changes by disabling all buttons (except the Lock button) on the front panel. This feature is useful in

Seite 29 - MASK MODE

page | 25The 16x16 3G-SDI Matrix w/ Push Button Controls supports both RS-232 and RS-485 protocols. In general, RS-485 (a superset of RS-422) is used

Seite 30

page | 26Routing Sources using the IR Remote ControlThe included IR Remote Control unit provides discrete routing between each input and output.The IR

Seite 31

page | 27 4. After the input has been selected, the LCD will indicate that the routing was successful. routing C

Seite 33

16 16xSOURCESDISPLAYS3G-SDI Matrixw/ Push Button Controls03 Advanced OperationRS-232 and IP Conguration ...

Seite 34 - LOCK MODE

iv16x16 3G-SDI Matrix w/ Push Button ControlsGefen, LLC c/o Customer Service 20600 Nordhoff St. Chatsworth, CA 91311Telephone: (818) 772-9100

Seite 35 - Communication Settings

page | 30Advanced OperationRS-232 and IP CongurationRS-232 Interface Only TXD, RXD, and GND are used. RS232 SettingsDescription SettingBaud rate192

Seite 36 - Using the IR Remote Control

page | 31Advanced OperationRS-232 and IP CongurationIP CongurationThe 16x16 3G-SDI Matrix w/ Push Button Controls supports IP-based control using RS

Seite 37

page | 32Advanced OperationRS-232 / IP CommandsCommand Description#activeboloEnables the boot loader#checkrefDisplays the Ref In signal#fadefaultReset

Seite 38

page | 33#checkrefThe #checkref command displays information about the input signal on the Ref In connector.Syntax:#checkrefParameters:NoneExamples:#c

Seite 39 - 03 Advanced Operation

page | 34RS-232 / IP CommandsAdvanced Operation#prreftableThe #prreftable command displays the reference signal in tabular format.Syntax:#prreftablePa

Seite 40 - RS-232 and IP Conguration

page | 35Advanced OperationRS-232 / IP Commands#prwebaddThe #prwebadd command displays the current IP settings of the matrix.Syntax:#prwebaddParameter

Seite 41 - IP Conguration

page | 36RS-232 / IP CommandsAdvanced Operation#rmtiraddThe #rmtiradd command sets the IR channel of the matrix. The specied IR channel must match t

Seite 42 - RS-232 / IP Commands

page | 37RS-232 / IP CommandsAdvanced Operation#sgatewayThe #sgateway command sets the gateway (router) address of the matrix. Each number (parameter

Seite 43 - #fadefault

page | 38Advanced OperationRS-232 / IP Commands#sipaddThe #sgateway command sets the IP address of the matrix. Each number (parameter) in the IP addr

Seite 44 - #prreftable

page | 39RS-232 / IP CommandsAdvanced Operation#snetmaskThe #snetmask command sets the net mask of the matrix. Each number (parameter) in the net mas

Seite 45 - #prwebadd

vv3GSDI Audio Embedder• There is no internal scaling in the 16x16 3G-SDI Matrix w/ Push Button Controls. All of the attached monitors must be able t

Seite 46 - #rmtiradd

page | 40Advanced OperationRS-232 / IP CommandsmThe m command displays the current matrix status in tabular form. Do not precede this command with th

Seite 47 - #sgateway

page | 41RS-232 / IP CommandsAdvanced OperationrThe r command routes the specied input to the specied output. Do not precede this command with the

Seite 48 - Advanced Operation

Using the built-in Web ServerThe Web interface is divided into three main pages: View Matrix Status, Masking, and IP Conguration. Each of these pag

Seite 49 - #snetmask

page | 43Advanced OperationWeb InterfaceSwitch Click this button to route the current input and output selection(s).Outputs Click to place a check mar

Seite 50

page | 44Advanced OperationWeb InterfaceMaskingMatrix Status This section is carried over from the View Matrix Status page and displays the current ro

Seite 51

page | 45Advanced OperationWeb InterfaceSubmit Click this button to activate the current masking selection(s).Outputs Click the Active or Mask radio b

Seite 52 - Web Interface

page | 46IP CongurationThe information at the top portion of the screen displays the current IP conguration of the matrix. Use the elds under the

Seite 55

16 16xSOURCESDISPLAYS3G-SDI Matrixw/ Push Button Controls 04 AppendixWarning Messages ...

Seite 56

viFeatures• Supports resolutions up to 1080p, 1920x1200, and 2K.• Front panel control buttons for local switching.• Serial interface for remote con

Seite 57

page | 50AppendixWarning MessagesSystem FailureIn the case of a critical malfunction, the following warning message will be displayed on the front-pan

Seite 58

page | 51AppendixFirmware Upgrade ProcedureThe following items are required to update rmware:• GefenPRO 16x16 3GSDI Matrix• Computer running Window

Seite 59 - 04 Appendix

page | 52The 16x16 3GSDI Matrix contains a fuse as part of the internal power supply. This fuse can easily be replaced by using the following steps.

Seite 60 - Warning Messages

page | 53AppendixSpecicationsSupported FormatsStandards • SD-SDI (SMPTE 259M)• HD-SDI (SMPTE 292M)• 3G-SDI (SMPTE 424M)Resolutions (max.) • 1080p

Seite 61 - Firmware Upgrade Procedure

This product uses UL or CE listed power supplies.20600 Nordhoff St., Chatsworth CA 913111-800-545-6900 818-772-9100 fax: 818-772-9120www.gefen.c

Seite 63 - Specications

3GSDI Audio Embedder16x16 3G-SDI Matrix w/ Push Button ControlsTable of Contentsviii01 Getting StartedPanel Layout ...

Seite 64 - Gefen’s got it. ®

16x16 3G-SDI Matrix w/ Push Button ControlsTable of Contents04 AppendixWarning Messages ................